Dry Verge System
Universal Dry Verge is a for a strong, watertight verge without use of mortar, whilst retaining the traditional stepped appearance of a bedded verge.
Dry Verge is for a strong, watertight verge without the use of mortar. Universal, boxed and ready to use, Dry Verge retains the traditional stepped appearance of a bedded verge and is suitable for use with standard concrete interlocking tiles.
It's fast
Dry Verge is a fast and easy way to install a dry verge system. The mechanical fixing means that the verge units simply slot together and is far quicker than a traditional mortar bedded verge.
It's value for money
Competitively priced and all in one box, there are 28 left hand verge units and 28 right hand verge units ready to be used straight out of the pack.
It's Universal
Compatible for use with standard concrete interlocking tiles.
It's quality assured
Quality tested and complies with BS 5534.
It's maintenance free
The dry fix method offers speed of installation, long term economy and long term safety - no need to repair failing mortar.
Dry Verge Refurbishment Kit
The Marley Dry Verge Refurbishment Kit enables damaged concrete verges to be repaired using the Marley Universal and Edgemere Dry Verge Systems or even to replace the verge before the problem hits, offering home-owners a maintenance-free and weather-tight solution.
10mm and 25mm Eaves Vent System
Marley Eternit universal eaves ventilation systems are designed to provide continuous 10mm and 25mm free vent areas to roof voids in an efficient and unobtrusive manner.
Designed to provide continuous 10mm or 25mm free vent areas to roof voids, Universal Eaves Vent provides an efficient and unobtrusive roofing solution. Once again, this universal Marley system is suitable for use with virtually all tiles and slates.
It's fast
The 6m Continuous Rafter Roll makes for a quick and simple installation process. The length of the rafter simply rolls out along the length of the eaves.
It's value for money
All the components required to install the Eaves Vent System is contained in one handy 6m box.
It's Universal
Compatible for use with all tiles and slates.
It's quality assured
Quality tested and complies with BS 5250.
HipFast
HipFast is a dry fix hip system that can be used with all tiles, slates and standard hip tiles. Quick and easy to fix, all of the components you need to install a HipFast system are available in just one box.
For use with clay, fibre cement, concrete tiles and slates.
Universal HipFast is a dry fix hip system that is compatible with all tiles, slates and standard hip tiles.
It's fast
Universal HipFast is quick and easy to install, thanks to its mechanical fixing method and the simple roll out operation of the hip roll.
It's value for money
All of the HipFast components are available in just one box and have enough product to fix a 6m length hip.
It's Universal
HipFast can be used with other manufacturers’ tiles, slates and standard hip tiles, not just Marley Roofing’s.
It's quality assured
As you would expect, HipFast passes all the necessary standards with flying colours. Tested and complies with BS 5534.
It's maintenance free
The dry fixing method offers considerable advantages, not only in the speed of installation, but also in long-term economy.
Universal RidgeFast System
Universal RidgeFast is a low cost, ventilated dry ridge system designed specifically to provide a quick and easy way to install a ventilated dry ridge, without compromising efficiency or cost effectiveness.
Universal RidgeFast is a low cost, ventilated dry ridge system suitable for use with all standard ridges, tiles and slates.
Its fast
Universal RidgeFast is the fast and easy way to install a ventilated dry ridge. This unique system is designed to simply roll out along the ridge and is far quicker than mortar bedding.
It's value for money
Everything that’s needed for a perfect ventilated ridge is in one handy 6m box and is competitively priced compared to similar systems.
It's Universal
Thanks to a unique fixing system Universal RidgeFast can be used with all standard ridges, tiles and slates. The 6 metre roll is easily moulded to the shape of any tile or slate and the grey colour of the side flashing replicates a mortar finish.
It's quality assured
It may be competitively priced but, just like all Marley Eternit products, Universal RidgeFast passes all the necessary standards with flying colours. Tested and complies with BS 5534 and BS 5250.
It's ventilated
Provides a minimum ventilated area of 5,000mm per linear metre and is suitable for ventilating flat tiles. Specially designed blanking strips allow you to use Universal RidgeFast with ridge and gas vent terminals.
It's maintenance free
The dry fixing method offers considerable advantages, not only in the speed of installation, but also in long-term economy and safety.
Universal Tile Vent
The Universal Tile Vent is designed for roof void ventilation and connection to 110mm soil pipe or mechanical extract systems. It is suitable for use with most popular large format and '15x9' interlocking tiles profiles at roof pitches 20° and above.
The Universal tile vent provides 15,000mm² of vent area. The vent is designed for roof void ventilation and connection to 110mm soil pipe or mechanical extract systems. It is suitable for use with most popular large format and '15 x 9' interlocking tile profiles at roof pitches of 20° and above.
Its fast
Universal Tile Vent is a fast and easy way to ventilate the roof.
It's value for money
Competitively priced and all in one box, ready to be used straight out of the pack.
It's Universal
Compatible for use with all large format and '15 x 9' interlocking tiles.
It's quality assured
Quality tested and complies with all the relevant Building Standards.
Ventilated Dry Ridge System
Suitable for steep pitched roofs up to 55º. A durable, unobtrusive and easily installed dry fix system for duo pitch applications to ventilate the apex of the roof.
For use with fibre cement, concrete tiles and slates.
Suitable for steep pitches up to 55° the Marley Ventilated Dry Ridge System remains one of the most simple, aesthetically pleasing and effective means to provide continuous ventilation along the length of the ridge for the removal of stagnant, moist air which would otherwise be trapped in the roof apex.
Authority
Correct use of the Marley Ventilated Dry Ridge and Dry Mono-Ridge Systems will meet the requirements of The Building Regulations 1991 as amended, Approved Document F2, The Building Standards (Scotland) Regulations 1990 - 1994 Part G, where appropriate and BS 5250. When fixed in accordance with installation instructions, the system meets the requirements of BS 5534 : Part 1 for the mechanical fixing of ridge tiles. Agrément Certificate No 86/1646 applies to Ventilated Dry Ridge.
Composition
Extruded black PVC-u Batten section, 3 metres long, with vacuum formed high impact polystyrene profiled Filler Units and injection moulded PVC-u Ridge Unions and Ridge End Caps. Nails are manufactured from durable aluminium and screws from stainless steel.
Performance
The Ventilated Dry Ridge system provides for the ventilation of the roof apex with mechanical fixing of ridge tiles, is completely weatherproof and of long proven durability.
When fixed in accordance with installation instructions, the Ventilated Dry Ridge system meets the requirements of BS 5534 : Part 1 for the mechanical fixing of ridge tiles.
The system provides 5,000mm²/lin.m. metre free area ventilation.
Compatibility
Suitable for all duo and mono-pitched roofs of 15° - 55° the Ventilated Dry Ridge system is fully compatible with Marley Ventilation and Dry Fix products. Combined with either 10mm or 25mm Eaves Ventilation Systems, it provides ventilation to the whole roof.
Description
* Extruded black PVC-u batten section, 3m long, nailed to each side of the ridge apex replacing the top tiling battens. Ventilation slots are located in the top flange of the batten section.
* A full range of vacuum formed high impact polystyrene profiled filler units (300mm cover), either vented to allow air flow or non-vented to prevent ingress of noxious fumes or gases, fit onto the top course of roof tiles.
* Injection moulded PVC-u Ridge Unions with attached rubber seals secure ridge tiles to the batten section. Unions are manufactured in three colours; grey, brown and terracotta.
* Ridge End Caps to suit Segmental, Modern and Segmental Mono-Ridge are manufactured in three colours to match ridge unions.
* Ventilated Dry Ridge utilises the standard Modern and Segmental Ridge profiles and may be used with Decorative Ridges, Gas Vent, Soil Pipe and Ridge Vent Terminals, adopting the normal fixing procedure and using PVC-u Ridge Unions.
* Ventilated Dry Mono-Ridge is available for use with the Segmental Mono-Ridge tile and suitable for all concrete tile profiles.
Ventilated Dry Mono-Ridge System
A durable, unobtrusive and easily installed dry fix system for mono pitch applications to ventilate the apex of the roof.
For use with fibre cement, concrete tiles and slates.
Authority
Correct use of the Marley Ventilated Dry Ridge and Dry Mono-Ridge Systems will meet the requirements of The Building Regulations 1991 as amended, Approved Document F2, The Building Standards (Scotland) Regulations 1990 - 1994 Part G, where appropriate and BS 5250. When fixed in accordance with installation instructions, the system meets the requirements of BS 5534 : Part 1 for the mechanical fixing of ridge tiles. Agrément Certificate No 86/1646 applies to Ventilated Dry Ridge.
Composition
Extruded black PVC-u Batten section, 3 metres long, with vacuum formed high impact polystyrene profiled Filler Units and injection moulded PVC-u Ridge Unions and Ridge End Caps. Nails are manufactured from durable aluminium and screws from stainless steel.
Performance
The Ventilated Dry Mono-Ridge system provides for the ventilation of the roof apex with mechanical fixing of ridge tiles, is completely weatherproof and of long proven durability.
When fixed in accordance with installation instructions, the Ventilated Dry Mono-Ridge system meets the requirements of BS 5534 : Part 1 for the mechanical fixing of ridge tiles.
The system provides 5,000mm²/lin.m. metre free area ventilation.
Compatibility
Suitable for all duo and mono-pitched roofs of 15° - 45° (Plain tiles 55°), the Ventilated Dry Mono-Ridge system is fully compatible with Marley Ventilation and Dry Fix products. Combined with either 10mm or 25mm Eaves Ventilation Systems, it provides ventilation to the whole roof.
Description
* Extruded black PVC-u batten section, 3m long, nailed to each side of the ridge apex replacing the top tiling battens. Ventilation slots are located in the top flange of the batten section.
* A full range of vacuum formed high impact polystyrene profiled filler units (300mm cover), either vented to allow air flow or non-vented to prevent ingress of noxious fumes or gases, fit onto the top course of roof tiles.
* Injection moulded PVC-u Ridge Unions with attached rubber seals secure ridge tiles to the batten section. Unions are manufactured in three colours; grey, brown and terracotta.
* Ridge End Caps to suit Segmental, Modern and Segmental Mono-Ridge are manufactured in three colours to match ridge unions.
* Ventilated Dry Ridge utilises the standard Modern and Segmental Ridge profiles and may be used with Decorative Ridges, Gas Vent, Soil Pipe and Ridge Vent Terminals, adopting the normal fixing procedure and using PVC-u Ridge Unions.
* Ventilated Dry Mono-Ridge is available for use with the Segmental Mono-Ridge tile and suitable for all concrete tile profiles.
Fibre Cement Ridges
A range of fibre cement dry fix ridges are available.
The fibre cement Duo-pitch ridge provides a dry-fixed, flush and weather tight ridge line.
Gas Ventilation Ridge Terminal
An effective answer to gas flue termination at the ridge. Designed solely as a ridge terminal for gas flues connected to gas appliances of rated input not exceeding 60Kw.
For use with concrete tiles and slates.
The effective answer to gas flue termination at the ridge.
The Gas Ventilation Ridge Terminal is designed solely as a ridge terminal for gas flues connected to gas appliances of rated input not exceeding 60Kw. The Gas Ventilation Ridge Terminal may either be bedded or used with the Dry Ridge System. Suitable for most duo-pitch roofs up to 60° pitch.
Authority
Gas Ventilation Ridge Terminals should be fitted in accordance with the requirements of The Building Regulations, Approved Document J, The Building Standards (Scotland) Regulations 1990 - 1994 Part F and comply with BS 5440 : Part 1. Tested and Approved by Advantica Technologies Ltd.
Composition
Concrete composite ridge tile base and hood, with stainless steel grille and bolts and aluminium throat extension box. Gasket set with locking washers available.
Performance
The Marley Gas Ventilation Ridge Terminal provides for the termination of gas appliances of rated input up to 60Kw, when connected via an 'R' Type Adaptor (not supplied), to a fully supported duct not exceeding 150mm diameter.
Compatibility
Suitable for all roofs of 15° - 60°, Marley Gas Ventilation Ridge Terminals may be either mortar bedded or installed with the Marley Ventilated Dry Ridge System. Gas Ventilation Ridge Terminals are compatible with the range of Marley Ventilation products and can only be used to terminate gas appliances of rated input up to 60Kw. Connection via the “R” type adaptor (not supplied) can accommodate up to 150mm diameter ductwork.
Designers and installers should check with the boiler/gas appliance manufacturer to establish suitability for use in the circumstances proposed. The terminal is not suitable for coal, wood or oil fired appliances, or for roof void, mechanical or passive ventilation systems.
Installation
If a ridge board is used in the roof construction, it should be cut and trimmed for a length of 400mm,with the roof underlay cut, and top batten positioned, a minimum of 25mm from the throat extension.
When used with the ventilated dry ridge system, a piece of the back of the batten section may require removal to facilitate the PVC-U riser. Blocked filler units are required for a distance of 600mm either side of the Terminal. A special adaptor ridge union is available to suit Modern ridge tile applications.
Description
* Concrete composite ridge tile and hood, in colours to match or complement the roof tiles.
* Stainless steel mesh grille allows gases to exhaust whilst preventing access to birds and vermin.
* Easily connects to fully supported internal flues by bolting an "R" type adaptor (not supplied) to throat extension.
Ridge Ventilation Terminal
The Ridge Ventilation Terminal is a weatherproof multi-purpose ridge terminal Completely weatherproof.
For use with concrete tiles and slates.
Ridge Ventilation Terminals provide a weatherproof multi-purpose ridge terminal. Completely weatherproof, this terminal offers an alternative method of ridge ventilation to the Ventilated Dry Ridge System and may be connected to a mechanical extract system or Passive Stack Ventilation.
Authority
Correct use of Marley Ridge Ventilation Terminals will meet the requirements of The Building Regulations 1991 as amended, Approved Document F2, The Building Standards (Scotland) Regulations 1990 - 1994 Part G, where appropriate and BS 5250. Agrément Certificate No 89/2223 applies to the use of this terminal for roof ventilation and mechanical extract systems.
Composition
Injection moulded dark grey PVC-u ventilation cowl and riser, sealed and bolted to Segmental profile concrete ridge tile. Injection moulded dark grey PVC-u Adaptor with Polypropylene Flexible Pipe (in Plumbers Accessory Pack).
Performance
The Marley Ridge Ventilation Terminal provides for the ventilation of the roof apex, and when connected via the Adaptor and Flexible Pipe, is also suitable for use with mechanical extract systems, or Passive Stack ventilation. The Ridge Ventilation Terminal provides 9,500mm² free area ventilation and has been tested by BSRIA to determine pressure resistance (Pa) values as detailed in the table below.
Compatibility
Suitable for all roofs of 15° - 60°, Marley Ridge Ventilation Terminals may be either mortar bedded or installed with the Marley Ventilated Dry Ridge System. Ridge Ventilation Terminals are compatible with the range of Marley Ventilation products and can be used to supplement either 10mm or 25mm Eaves Ventilation Systems. Connection to mechanical or passive ventilation systems can accommodate 82mm - 110mm diameter ductwork. The terminal is not suitable as an exhaust for hot gases.
Installation
Ridge Ventilation Terminals should be installed in a horizontal position, clear of any obstructions likely to hinder the airflow of exhaust fumes and 600mm away from any Gas Ventilation Ridge Terminal or other flue outlet. If a ridge board is used in the roof construction, it should be cut and trimmed for a length of 400mm, with the roof underlay cut and formed to fit neatly to the sides of the riser. When used with the Ventilated Dry Ridge System, a piece of the back of the Batten Section may require removal to facilitate the PVC-u riser. Blocked Filler Units are required for a distance of 600mm either side of the terminal, if connected to a mechanical extract system. A special Adaptor Ridge Union is available to suit Modern ridge tile applications.
Description
* Concrete Segmental Ridge tile base, in colours to match or complement the roof tiles.
* Fully weatherproof injection moulded PVC-u cowl and riser incorporates deflectors and ventilation slots to prevent ingress of wind driven rain and snow. The cowl is bolted to the ridge base and is grey in all cases.
* Can be connected to fully supported 110mm internal pipework by using a PVC-u adaptor and flexible pipe.
* Wind tunnel tested.
* Performance tested by BSRIA.
* This product is NOT suitable as an exhaust for hot gases
In-Line Clay Tile Vent
The Marley Eternit in-line clay tile vent provides 7500mm2 free airspace.
For use with clay plain tiles.
The Marley Eternit in-line clay tile vent provides 7,500mm² free airspace.
The in-line clay tile vent offers a practical and unobtrusive solution to the problem of roof space ventilation.
The vent is also suitable for terminating soil and vent pipes and mechanical ventilation, as well as passive stack ventilation. For these applications a detachable extension sleeve is supplied, and an optional 100/125/150mm stepped pipe adaptor is also available.